EasyManua.ls Logo

3Com Router 3012 - Illegible Characters Display on the Terminal after Power-On

3Com Router 3012
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50 CHAPTER 5: TROUBLESHOOTING
Illegible Characters
Display on the
Terminal after
Power-On
If the system operates normally after the system runs the POST, the start-up
information is displayed on the console terminal. If the configuration system has a
fault, the terminal may display only illegible characters.
If the console terminal displays illegible characters after the POST, verify that the
HyperTerminal parameters are set properly, as follows:
■ Baud: 9600
■ Data bits: 8
■ Stop bit: 1
■ Parity: None
■ Flow control: None
■ Terminal emulation: VT100
If the parameter settings do not match these values, reconfigure them.