Elipar
S10
LED Curing Light
   
 
   
LED svjetiljka za polimerizaciju
Gyors polimerizációt biztosító LED-lámpa
Diodowa lampa do polimeryzacji
Lampă de fotopolimerizare LED
LED Polymerizačná lampa
Polimerizacijska LED luč
LED polymerační lampa
LED Işık Cihazı
LED-valguslamp
Gaismas diodes lampa
Diodinis švitintuvas
вітлодіодна фотополімерна лампа
uk
lt
lv
et
tr
cs
sl
sk
ro
pl
hu
hr
bg
ru
en
Operating Instructions Navodila za uporabo
  
Návod k použití
  
Kullanma Talimatları
Upute za upotrebu Kasutusjuhend
Használati utasítás Lietošanas pamācība
Instrukcja użycia Naudojimo instrukcija
Instrucţiuni de utilizare
Інструкції з використання
Návod na použitie

Table of Contents

Questions and Answers

  • A
    Amber RiddleAug 7, 2025
    What does it mean if the 3M ESPE Elipar S10 Dental equipment handpiece flashes red while charging?
    • A
      Anita CarrilloAug 7, 2025
      If the power level display on your 3M ESPE dental handpiece flashes red while it's in the charger, it indicates a charging problem. This usually means the battery is defective or has reached the end of its useful life. Replace the battery to solve this issue.
  • M
    Matthew HuffmanAug 12, 2025
    Why does the light not turn on and an error signal sound on my 3M ESPE Elipar S10?
    • R
      ruizvalerieAug 12, 2025
      If the light emission doesn't start when you press the START button and a 2-second error signal sounds on your 3M ESPE dental handpiece, it means the handpiece has overheated during use. Allow the handpiece to cool for 3 minutes before attempting another exposure by pressing the START button.
  • J
    jessealvarezAug 19, 2025
    What to do if the 3M ESPE Dental equipment handpiece flashes red and won't activate?
    • A
      Andrea StanleyAug 19, 2025
      If the power level display on your 3M ESPE dental handpiece flashes red, the exposure is interrupted, and the device goes into sleep mode, it means the battery doesn't have enough charge. Place the handpiece in the charger to recharge the battery.
  • A
    Andrew MillerAug 25, 2025
    How to turn on a 3M ESPE Elipar S10 Dental equipment handpiece after long storage?
    • A
      Annette YoderAug 25, 2025
      If your 3M ESPE dental handpiece won't turn on after a long period of non-use, the battery likely doesn't have enough charge. Place the handpiece in the charger and allow it to recharge.
  • T
    Todd JoyceAug 30, 2025
    Why is the charge level display on my 3M ESPE Elipar S10 handpiece glowing red?
    • G
      garyyoungAug 30, 2025
      If the charge level display on your 3M ESPE dental handpiece glows red steadily, it indicates that the remaining battery charge is only adequate for approximately 5 to 10-second exposure cycles. To resolve this, place the handpiece in the charger and recharge the battery.

Summary

Safety

Fields of Application

Details the intended uses and applications of the Elipar S10 curing light.

Technical Data

Provides detailed specifications for the charger and handpiece.

Product Description

Charger

Specifications for the charging unit, including voltage and power.

Handpiece

Specifications for the handpiece, including power source and wavelength.

Technical Data

Charger and Handpiece

Inserting the Battery

Instructions for properly inserting the battery into the handpiece.

Battery Charging

Operation

Selection of Exposure Time

Explains how to choose and set the light exposure time.

Activating and Deactivating the Light

Step-by-step instructions for turning the curing light on and off.

Positioning the Light Guide

Guidance on correctly positioning the light guide for optimal polymerization.

Measurement of Light Intensity

Describes how to measure and check the light intensity using the charger.

Sleep Mode

Acoustical Signals - Handpiece

Troubleshooting

Maintenance and Care

Inserting;Removing the Battery

Step-by-step guide for safely inserting and removing the battery.

Handpiece;Battery Care

Recommendations for caring for the handpiece and battery.

Cleaning the Light Guide

Detailed instructions for cleaning and disinfecting the light guide.

Material Resistance

Pre-Treatment

Manual Cleaning and Disinfection of the Light Guide

Detailed procedures for manual cleaning and disinfection of the light guide.

Automatic Cleaning;Disinfection

Information on automated cleaning and disinfection processes.

Sterilization

Guidelines for effective sterilization procedures, primarily steam.

Sterilization

Check

Steps to perform a check of the light guide before reuse.

Clean Charger, Handpiece, and Glare Shield

Instructions for cleaning the charger, handpiece, and glare shield.

Storage of the Handpiece during Extended Periods of Non-Use

Guidance on how to store the handpiece when not in use for extended periods.

Appendix

Guidance and manufacturer’s declaration - electromagnetic emission

Provides information and declarations regarding electromagnetic emissions from the device.

Guidance and manufacturer’s declaration - electromagnetic immunity

Recommended separation distance

Specifies recommended distances for RF equipment to maintain proper operation.

3M ESPE Elipar S10 Specifications

General IconGeneral
Brand3M ESPE
ModelElipar S10
CategoryDental equipment
LanguageEnglish