9 / 11
MO 0765-0601
740
wrist strap + shoe tester
3
<
>
o.k.
12
2 -
5 -
10 -
35 -
- 10
- 35
- 50
- 100
on / off
+
-
Output
R
max
DC 24
30 V / 150 mA
11.1 M
AB
Verification of shoe test circuit:
Connect the reference resistor to the 740 as shown
in Figure 2. Select the 10 M range using the
reference resistors indicated in the test table and
press contact plate B.
The LEDs will indicate as shown below. Repeat
this procedure for 35, 50 and 100 M ranges.
Reference Resistance LED -
resistor range settings Indication
750 k 10 M - range Red
900 k Green
9.0 M Green
*>11.0 M Red
31.5 M 35 M - range Green
>38.5 M Red
45.0 M 50 M - range Green
>55.0 M Red
80.0 M 100 M - range Green
>120.0 M Red
*This example is used above