3M 8822
Particulate Respirator
User Instructions
IMPORTANT: Keep these User Instructions for reference
IMPORTANT
Before use, the wearer must read and understand these User Instructions. Keep these instructions
for reference. See information supplied by the manufacturer.
Use For
Mechanically and thermally generated particulates in concentrations up to ten (10) times the
Exposure Standard. For example, sanding, drilling, grinding, crushing, sweeping, brezing, oxy-
cutting and welding. This respirator may also help reduce breathing in pathogenic biological
airborne particulates such as influenza virus, but does not eliminate the risk of infection or disease.
Warning
Always be sure that the complete product is suitable for the application, fitted correctly,
worn during all periods of exposure and replaced when necessary.
Proper selection, training and use are essential in order for the product to help protect the
wearer from certain airborne contaminants. Failure to follow all instructions and limitations
and/or failure to properly wear the respirator during all periods of exposure may adversely
affect the wearer’s health, lead to severe or life-threatening illness or permanent disability.
For suitability and proper use, follow local regulations, refer to all information supplied or
contact an occupational hygienist, safety professional or 3M representative on the Tech
Assist Helpline 3M Australia 1800 024 464, 3M New Zealand 0800364 357.
Before use, the wearer must be trained in use of the complete product in accordance with
applicable Health and Safety standards/guidance.
These products do not contain components made from natural rubber latex.
These products do not protect against gases/vapours.
Do not use in atmospheres containing less than 19.5% oxygen. (3M definition. Individual
This respirator helps protect against certain particles. Misuse can result in sick
ness or death. For proper use, see supervisor or User Instructions on package or
call 3M, 400-920-3595. For US, call 1-800-243-4630.

Other manuals for 3M 8822

Question and Answer IconNeed help?

Do you have a question about the 3M 8822 and is the answer not in the manual?

3M 8822 Specifications

General IconGeneral
Brand3M
Model8822
CategoryRespiratory Product
LanguageEnglish

Summary

Use For

Safety Warnings and Usage

Suitability and Proper Use

Ensure product suitability, correct fitting, and adherence to instructions for protection.

Training and Compliance

Wearer must be trained; follow regulations and consult professionals for proper use.

Material and Protection Limitations

Product contains no natural rubber latex, does not protect against gases/vapours.

Oxygen Deficiency and Unknown Atmospheres

Do not use in atmospheres with less than 19.5% oxygen or unknown/immediately dangerous concentrations.

Facial Hair and Seal Integrity

Do not use with facial hair that may inhibit a good face seal.

Fit Testing and Inspection

Recommended fit testing per AS/NZS 1715. Inspect for damage before each use.

Immediate Action and Replacement

Leave area if breathing is difficult. Discard if damaged or resistance increases.

Modification and Temperature Limits

Never alter the device. Max operating temp +50°C; beware of freezing valves in moisture.

Storage and Transportation

Storage Instructions

Store in accordance with manufacturer's instructions, using original packaging.

Notes on Conditions and Shelf Life

Shelf Life

Unopened product shelf life is 3 years from date of manufacture. Check before use.

Fitting Instructions

Step-by-Step Fitting

Detailed steps for cupping, positioning, strap adjustment, nosepiece moulding, and fit checks.

Fit Check Importance

Crucial to press nosepiece firmly for a good seal. Do not enter hazardous area if fit is poor.