EasyManua.ls Logo

3M CWS Series - Valve History and Error Codes

3M CWS Series
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Valve History
(Step 1) Press or simultaneously for 3 seconds and release. Then press and simultane-
ously and release. If screen, to the left, does not appear is 5 seconds the lock on the valve is acti-
vated. To unlock press , NEXT, and SET CLOCK in sequence, then press and . Then press
and simultaneously and release.
(Step 2) Software Version: This display shows the software version of the valve. Press the NEXT but-
ton to go to the next step or press REGEN to exit Valve History.
(Step 3) Maximum fl ow rate since startup: This display shows the maximum fl ow rate in gallons per
minute that has occurred since startup. This display will equal zero if a water meter is not function-
ing. Press the NEXT button to go to the next step. Press REGEN to return to previous step.
(Step 4) Total gallons used since start-up: This display shows the total gallons. This display shows
the total days since start-up. Press the NEXT button to go to the next step. Press REGEN to return to
previous step.
(Step 5) Total days since start-up: This display shows the total days since start-up. Press the NEXT but-
ton to go to the next step. Press REGEN to return to previous step.
(Step 6) Total number of regenerations since start-up: This display shows the total number of re-
generations that have occurred since system start-up. Press the NEXT button to go to the next step.
Press REGEN to return previous step.
(Step 7) Number of error occurrences since start-up: This display shows E and the total number of
errors that have occurred since system start-up. Press the NEXT button to exit Valve History. Press
REGEN to return to previous step. To lock settings press , NEXT, and SET CLOCK in sequence.
3-3
RETURN TO
NORMAL MODE
Step 1
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7