Use Replacement Cartridge 3MFF101
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53.
Capacity 6000 Gallons
(22,712 Liters) Contaminant Reduction Determined by NSF testing.













Chlorine Taste and Odor 1.9 mg/L 2.0 mg/L ± 10% 97.3% 0.05 mg/L N/A 50% J-00074328
Nominal Particulate Class I, ,
0.5 to < 1.0 µm 5,966,667
pts/mL At least 10,000 particles/mL 99.9% 5517 pts/ml N/A 85% J-00037739
Benzene 0.014 mg/L 0.015 mg/L ± 10% 96.4% 0.005 mg/L 0.005 mg/L N/A J-00074324
Cyst* 122,500 cysts/L Minimum 50,000 cysts/L 99.99% <1 cyst/L N/A 99.95% J-00037737
Lead pH @6.5 0.148 mg/L 0.15 mg/L ± 10% >99.3% 0.001 mg/L 0.010 mg/L N/A J-00074321
Lead pH @8.5 0.153 mg/L 0.15 mg/L ± 10% >99.3% 0.001 mg/L 0.010 mg/L N/A J-00074322
P-Dichlorobenzene 0.235 mg/L 0.225 mg/L ± 10% 99.7% 0.0005 mg/L 0.075 mg/L N/A J-00074326
Toxaphene 0.015 mg/L 0.015 mg/L ± 10% 93.1% 0.001 mg/L 0.003 mg/L N/A J-00074327
* Based on the use of Cryptosporidium parvum oocysts.

Service Flow 2.5 gpm (9.46 lpm)
Water Supply Potable Water
Water Pressure 30 -125 psi (207 – 862 kPa)
Water Temperature 40º F - 100º F (4.4º C - 38º C)
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements
be carried out for the product to perform as advertised. See Installation Manual for Warranty information.
While the testing was performed under standard laboratory conditions, actual performance may vary.
Replacement Cartridge: 3MFF101 For estimated costs of replacement elements please call 1-800-222-7880 or visit
our website at
www.3Mpurification.com



Systems certified for cyst reduction may be used on disinfected
water that may contain filterable cystsEPA Establishment Number 070595-CT-001
Parts and service available from:
3

400 Research Parkway
Meriden, CT 06450, U.S.A.
Tel (800) 222-7880 3M is a trademark of 3M Company.
(203) 237-5541 © 2010 3M Company. All rights reserved.
Fax (203) 238-8701 NSF is a trademark of NSF International
www.3Mpurification.com INSTR2213 0410

































System tested and certified by NSF International against NSF/ANSI Standard
42 and Standard 53 for the reduction of substances listed below.