1.Water is salty
a. Salt setting is too high
b. Cyclone (distributor) tube too short
c. The inlet pressure is too low and unable o
    flush out the drainage pipe
a. Check salt setting
b. Replace
c. Increase the water pressure with a booster
    pump to flush the drainage pipe and check
    or it need to replace the brine valve tank
2.Timer does not display 
   time of day
a. AC adapter unplugged
b. No electric power at outlet
c. Defective AC adapter
d. Defective PC board
a. Connect power
b. Repair outlet or use working outlet
c. Replace AC Adapter
d. Replace PC board
3.Timer does not display 
   correct time of day
a. Switched outlet
b. Power outage
c. Defective PC board
a. Use uniterepted outlet 
b. Reset time of day
c. Replace PC board
4.Timer display incorrect 
   regeneration time
a. Power outage
b. Time is set incorrectly
c. The regeneration time is not correct
d. Faulty board
e. PC board incorrectly aligned to drive bracket
a. Reset time of day 
b. Reset time of day
c. Reset the regeneration time
d. Replace circuit board
e. Ensure PC board is correctly snapped on 
    to drive bracket
5.Control valve stalled in 
   regeneration
a. Motor not operating
b. No electric power at outlet
c. Defective AC Adapter
d. Defective circuit board
e. Broken drive gear or drive capassembly cap
f. Broken piston retainer
g. Broken main or regenerant piston
a. Replace the motor
b. Repair outlet or use working outlet
c. Replace AC Adapter
d. Replace circuit board
e. Replace drive gear or drive
f. Replace drive cap assembly
g. Replace main or regenerant piston
6.Control valve does not 
   regenerate automatically 
   but does when "REGEN" 
   button is depressed
a. By-pass valve in bypass position 
    operation position
b. Meter connection disconnected
c. Restricted/salted meter turbine
d. Defective meter
e. Defective circuit board
f. Set-up error
a. Put bypass valve in normal
b. Connect meter to PC board
c. Remove meter and check for rotation
    or foreign matter
d. Replace meter
e. Replace circuit board
f. Check control valve set-up procedure
7.Time of day flashes 
on and off
a. Power has been out more than two hours, 
    the AC Adapter was unplugged and then 
    plugged back into the wall outlet, the 
    AC adapter plug was unplugged and then 
    plugged back into the board or the NEXT 
    and REGEN buttons were pressed to reset 
    the valve
a. Reset the time of day
Control valve failure  error codes
Error codes
101
102
103
104
109
201
Error message
Un able to detect control valve operation
Unexpected stall
Control valve piston not in home 
position seconds
Program error
Program error (runtime error)
Unable to proceed to next function
Possible solutions
Press NEXT and REGEN for 3 seconds
Check motor and replace if need;
Reinstall or replace PC board
Check motor and replace if need;
Reinstall or replace PC board;
Clean or replace drive gear.
Press NEXT and REGEN for 3 seconds 
or unplug power source jack (black wire)
and plug back in to reset control valve
Check piston and spacer stack valve assembly
Reinstall or replace PC board  
Reinstall or replace PC board
Faults 
Analysis
Solutions