To turn the unit off:
For Ambient Air:
Turn off the ozone switch.
Wait 10 seconds before continuing.
Turn off the air compressor switch.
For Oxygen Air:
Turn off the ozone switch.
Wait 10 seconds before continuing.
Turn off the oxygen source.
Tube Connection and Start Up
An oxygen tank or oxygen generator can be used.
Using Oxygen Bottle/Tank:
Connect oxygen bottle/tank to ozone generator (Oxygen In Port).
Connect MP-3000 (110V) Ozone Generator (Ozone Out Port) to venturi injector.
Install a check valve 10 inches after ozone outlet tube fitting. This can be done by cutting
the tube ten inches after ozone outlet fitting.
Connect both ends of cut tubes to the check valve. Please direct the arrow on the check
valve toward venturi injector.
Set tank gas flow meter at 2-4 liters per minute and 5 PSI maximum.
First, open the oxygen valve. Then turn on the main ozone power switch on the front panel
of the MP-3000. The internal air compressor switch stays OFF. The ozone light and fan
should turn on.
Increase power to the cells by turning the ozone concentration knob clockwise. Please
remember to make a full rotation clockwise.
Prior to shutting off the feed gas to the unit, turn off the switch and allow the unit to purge
for about 1 minute. Then, turn the flow of oxygen gas off.
NOTE: Do not turn the air pump switch ON when using an oxygen generator, oxygen bottle or
tank.
Using Oxygen Generator:
Connect oxygen generator (Oxygen Out Port) to ozone generator (O
2
In Port).
Connect MP-3000 (110V) Ozone Generator’s (Ozone Out Port) to the venturi injector.
Install a check valve 10 inches after ozone outlet tube fitting. This can be done by cutting
a tube ten inches after ozone outlet fitting.
Connect both ends of cut tubes to the check valve.