The test method for failure of the MP Series:
Check the power input for correct voltage (110V).
If the unit is on but no ozone is being produced, this could be due to:
Overheating of the unit
Water back flow to the ozone generator
Turn off ozone generator and let air flow through the unit for five to ten minutes.
Check the fuse, change if needed.
The MP-3000 uses a 3 AMP fuse for the back rocker switch and a 5 AMP fuse in the
ozone board.
Check the air compressor line or oxygen input
If the generator is taking in oxygen, please check the tube inside the machine for kinks.
If the machine can produce some air, but the air is not ozone please check the following:
The ozone power indication lamp is lit
Check ozone control knob is set above 20%
If you are still experiencing problems, please contact A2Z Ozone at (502) 499-4977 or
service@a2zozone.com for more information.
1
Main Power
Switch
Powers the whole unit. If there is no power to the unit, check here
first.
2
Main Fuse
If no power to the unit, check the Main Power Switch first, then
check this fuse.
3
Spare Fuse
Holds spare 3A fuse.