Capacity | 200 g |
---|---|
Readability | 0.001 g |
Linearity | ±0.002 g |
Interface | RS-232C |
Calibration | External |
Power Supply | AC adapter (included) |
Operating Temperature | 5°C to 40°C |
Units | g, oz |
Repeatability | 0.001 g |
Expresses gratitude for purchasing the A&D balance.
Details the force restoration principle utilized by the balance.
Defines gravity and factors influencing its variation, affecting measurements.
Explains the process and importance of calibrating the balance for accuracy.
Lists optimal environmental and setup conditions for accurate weighing.
Advises on calibration frequency and the quality of calibration masses.
States the requirement for the balance to be warmed up before calibration.
Explains common error messages encountered during the calibration process.
Details the function and operation of the ON/OFF key for the display.
Explains the purpose of the MODE key in accessing parameter settings.
Describes the function of the PRINT key for data output.
Explains the RE-ZERO key's function for zeroing and taring.
Advises on when to disable Zero Track for improved accuracy with light samples.
Basic instructions for weighing an object on the balance.
Steps for calibration before performing weighing.
Procedure for weighing by adding material to a container.
Procedure for weighing by removing material from a container.
Instructions for utilizing the balance's underhook for measurements.
A practical example demonstrating density determination.
Instructions for accessing and replacing the internal fuse.
Adjusts stability band width for motion detection.
Sets filter strength based on environmental conditions.
Configures data output for RS-232C/CL interface.
Sets the baud rate for data transmission.
Defines transmission terminators for data communication.
Configures time-out settings for communication.
Step-by-step instructions for installing the RS-232C interface.
Technical specifications for the RS-232C interface.
Describes the format of data transmitted via the interface.
Details the pinout configuration for RS-232C communication.
Example BASIC program for NEC PC-9801.
Example BASIC program for IBM PC-XT (Stream Mode).
Example BASIC program for IBM PC-XT (Command Mode).
Explains the ON/OFF switch positions for normal operation and charging.
Guidelines for maintaining battery health and longevity.
Lists causes and solutions for a dark display.
Explains the meaning of a blank or dashed display.
Troubleshooting low battery indication.
Solutions for calibration errors.
Reasons and fixes for battery power failure.
Addresses issues with unstable weight readings.
Solutions for inconsistent weight measurements.
Troubleshooting incorrect measurement results.
Explains error codes E and -E on the display.
Solutions for calibration weight errors.
Solutions for a persistent dot on the display after RE-ZERO.
Troubleshooting battery recharge failures.