Type | Differential Pressure Transmitter |
---|---|
Output Signal | 4-20 mA, HART |
Power Supply | 10.5 to 42 V DC |
Process Connection | 1/4 - 18 NPT |
Process Temperature | -40 to 120°C (-40 to 248°F) |
Housing Material | Aluminum |
Protection Class | IP67 |
Electrical Connection | 1/2 - 14 NPT |
Provides an overview of safety aspects for device operation and installation.
Lists prohibited uses of the device to prevent hazards.
Specifies the essential technical limits that must be observed for safe operation.
Specifies that installation and maintenance must be by trained, authorized personnel.
Safety precautions for electrical connections and grounding.
Safety warnings and procedures for inspection and maintenance work.
Explains how to identify the instrument using data plates and certification marks.
General guidelines and warnings for installing the transmitter.
General advice on mounting, including factory config and hazardous area considerations.
Lists ATEX and FM certifications for hazardous area installations.
Guidance for mounting Differential Pressure (DP) sensor transmitters.
Guidance for mounting P-style pressure transmitters on pipes.
Key points to observe for correct impulse piping installation.
Guidance on process connections, adapters, and torque specifications.
General recommendations for impulse piping configuration based on application.
Specific installation steps for steam or clean liquid flow measurements.
Specific installation steps for gas or liquid flow measurements.
Installation for liquid level measurement in closed tanks with dry leg.
Installation for liquid level measurement in closed tanks with wet leg.
Wiring diagram and explanation for HART transmitter analogue output.
Procedures for correcting lower range value and zero shifts.
Methods for correcting installation-induced zero shifts.
Steps to configure Lower Range Value (LRV) and Upper Range Value (URV).
Using PV Zero Bias/Offset for zero shift correction.
How to configure the transmitter using the optional LCD HMI with keypad.
Configuration of fail-safe types, saturation limits, and alarm limits.
Options for local calibration of the instrument, including sensor trimming.
Step-by-step guide for easy setup of Standard HART transmitters.
Step-by-step guide for easy setup of Advanced HART transmitters.
Configuration options for device setup, including write protection.
Configuration of fail-safe types, saturation limits, and alarm limits.
Procedures for calibrating the pressure sensor and output.
Setup and configuration for totalizer functions, including units.
Monitoring diagnostic messages and performing loop tests.
How to configure the transmitter using PC/laptop or handheld terminal.
Lists communication board and electronic-related error messages.
Details error messages related to sensor failures or incompatibilities.
Lists error messages related to process conditions like overrange or saturation.
Procedures for replacing the pressure transducer.
Procedures for replacing the electronic module.
ATEX certifications and application examples for hazardous areas.
Details ATEX categories for gas/dust with Ex ia protection.
ATEX categories for gas/dust with Ex db and Ex tb protection.
ATEX categories for gas/dust with Ex ic and Ex tc protection.
FM Approvals standards and classifications for hazardous locations.
FM Approvals classifications for Groups, Divisions, Temp. Classes, Protection Types.