9.13 Installing the compressor casing
Fitting the wall insert and the diffuser
Fig.64: Fitting the wall insert and the diffuser
Product Size Tightening torque [Nm]
A150 M6 8
A155 M6 8
Table47: Tightening torque (79041)
1. Fit a new O-ring(77005).
2. Fit the swivel lifting eyes(S) to the wall insert(77000). Secure lifting gear to the swivel
lifting eye.
3. Install the wall insert(77000) into the compressor casing and, when doing so, pay atten-
tion to the positioning pin in the compressor casing.
4. Fit the diffuser(79000) with fixing discs(79040) and screws(79041). Observe the tight-
ening torque.