9.13 Installing the compressor casing
Fitting the wall insert and the diffuser
Fig.64: Fitting the wall insert and the diffuser
Product Size Tightening torque [Nm]
A150 M6 8
A155 M6 8
Table47: Tightening torque (79041)
1. Fit a new O-ring(77005).
2. Fit the swivel lifting eyes(S) to the wall insert(77000). Secure lifting gear to the swivel
lifting eye.
3. Install the wall insert(77000) into the compressor casing and, when doing so, pay atten-
tion to the positioning pin in the compressor casing.
4. Fit the diffuser(79000) with fixing discs(79040) and screws(79041). Observe the tight-
ening torque.