Type | AC Drive |
---|---|
Frequency Range | 0 to 500 Hz |
Storage Temperature | -40 to +70 °C |
Enclosure | IP21, IP54 |
Control Method | Scalar control, Vector control |
Communication | Modbus |
Protection Features | Overcurrent, Overvoltage, Undervoltage, Overtemperature |
Cooling Method | Air-cooled |
Relative Humidity | 5 to 95 % (non-condensing) |
Altitude | Up to 1000m without derating |
Ambient Temperature | -10 to +40°C |
Distinguishes warnings and notes in the manual for safety instructions.
Information on situations causing injury or equipment damage with safety symbols.
Safety instructions for electrical installation and maintenance of the ACX 600.
Details on door interlocked fused disconnect and input power disconnect for ACx 607/604.
Describes the internal ground fault protection and its potential impact on circuit breakers.
Requirements for emergency stop devices and their placement.
Warnings and guidelines for connecting motors to the ACx 600.
Explains requirements for motor insulation due to IGBT inverter technology.
Prohibits connecting PF correction capacitors between drive and motor due to damage risk.
Guidelines for using contactors with ACx 600, especially with DTC control mode.
Requirements for double/reinforced insulation for components connected to digital inputs.
Cautionary notes regarding transporting and lifting the ACx 607 unit.
Ensuring the environment is suitable for the ACx 600's service life and performance.
Checklist items for ambient temperature, altitude, air quality, and enclosure suitability.
Step-by-step guide for securing the ACx 607 cabinet to the floor.
Procedure to check insulation of the motor and cable between drive and motor.
Requirements for input power disconnecting means for ACx 607/604 units.
Information on internal and external input fuses for ACx 607 and ACx 604.
How the ACx 607 provides motor overload protection and when additional protection is needed.
Requirements for cable insulation voltage ratings based on drive voltage and motor connection.
Recommendations for wiring to ensure reliable operation and prevent problems like EMI.
Requirements for shielding control cables and managing signal wire twists.
Safety warning and procedure for connecting mains, motor, and control cables to ACx 607.
Procedure for adjusting transformer settings if they do not match the supply voltage.
Guidelines for electrically insulating tachometers to prevent current paths.
Warning about dangerous DC voltage on brake control terminals and resistor connection.
Checklist for mechanical and electrical installation before start-up.
Checklist items for ambient conditions, mounting, cooling air, and motor/equipment applicability.
Checklist items for EMC filters, grounding, input voltage, transformer settings, and connections.
Checklist for control connections, foreign objects, and bypass connection safety.
IEC ratings for ACx 604 and ACx 607 with 50 Hz and 60 Hz supplies.
NEMA ratings for ACS 604 and ACS 607 with 60 Hz supply.
Explanation of how ambient temperature affects output current and derating factors.
Table showing application program dependent features like preprogrammed faults and supervision functions.
Details on EMC requirements for industrial low-voltage networks and IT networks.
Requirement for symmetrical shielded motor cable and recommendations for mains cabling.