Do you have a question about the ABB ACS 607 and is the answer not in the manual?
Input Voltage | 380-480 V AC |
---|---|
Frequency | 50/60 Hz |
Altitude | Up to 1000 m without derating |
Communication Protocols | Modbus, Profibus, CANopen |
Enclosure Type | IP21, IP54 |
Protection Features | Overcurrent, Overvoltage, Undervoltage, Short circuit |
Ambient Temperature | -10°C to +40°C |
Storage Temperature | -40°C to +70°C |
Relative Humidity | 5-95% (non-condensing) |
Distinguishes warnings for serious conditions and notes for special attention.
Explains symbols for Dangerous Voltage, General Warning, and ESD.
Safety instructions for electrical installation and maintenance work on ACX 600 units.
Warnings regarding high voltages, capacitor discharge, and external control circuits.
Warning about adjusting motor speeds and suitability of driven equipment.
Warning about automatic reset functions and potential operational issues.
Safety regarding door interlocked disconnect and input power disconnect.
Explains internal ground fault protection and its disablement.
Requirements for operator control stations and ACx 600 E-stop functionality.
Warnings about motor nominal voltage/current and insulation resistance tests.
Details on motor insulation requirements due to IGBT inverter technology.
Table listing insulation requirements for motors based on type and voltage.
Diagram showing VPK and dv/dt as function of cable length without dv/dt filter.
Diagram showing VPK and dv/dt as function of cable length with dv/dt filter.
Warning against connecting PFC capacitors between drive and motor due to damage risk.
Safety for parallel PFC capacitors and DTC mode contactor operation.
IEC 664 requirements for double/reinforced insulation for input connections.
Safety precautions for transporting and lifting the ACx 607 unit.
Detailed meaning of ACx 604/607 type code characters for various selections.
Checklist items for ambient temperature, altitude, air quality, and enclosure adequacy.
Step-by-step procedure for securing the ACx 607 cabinet to the floor.
Procedure for checking motor and cable insulation resistance.
Warning against performing voltage tolerance or insulation resistance tests on ACx 600.
Guidelines for door interlocked fused disconnect and input power disconnect.
Information on required input fuses for ACx 600 protection.
How ACx 607 provides overload protection for the motor.
Recommendations for cable insulation voltage ratings based on drive voltage.
Important recommendations for ACx 600 wiring to ensure reliable operation.
Shielding requirements for control cables and twisting signal wires.
Procedure for connecting input power, motor, and control cables to ACx 607.
Procedure for adjusting transformer settings to match supply voltage.
General installation instructions for optional modules and Drive Window PC tool.
Information on braking chopper installation and warnings about brake control terminals.
Checklist for mechanical and electrical installation before ACx 600 start-up.
Guidance on derating output current based on ambient temperature.
Table of preprogrammed faults, programmable fault functions, and supervision functions.
IEC 664 insulation requirements for connecting thermistors and similar components.