INSTRUCTIONS
High
Impedance
Differential
Relay
©
CIRCUIT
0
SHIELD
Type
87
B
Catalog
Series
419
B
£
H I G H
-
I M P E D A N C E
O I F P E R E N T I A I
R E L A Y
*
®
0
2
SQ
*
a
too
.
t
?
s
#
'
400
TR
#
VOLTS
AC
RMS
SET
TES
1
ABB
Power
TSD
Company
A
-
f n
.
o w n
P
.
,
U S A
v
.
-
;
Courtesy of NationalSwitchgear.com
Question and Answer IconNeed help?

Do you have a question about the ABB Circuit Shield 87B and is the answer not in the manual?

ABB Circuit Shield 87B Specifications

General IconGeneral
TypeDifferential Protection Relay
Rated Frequency50/60 Hz
Model87B
StandardIEC 60255
Operating Time20 ms
Communication InterfacesIEC 61850
Protection FunctionsDifferential protection, Overcurrent
Operating Temperature Range-25°C to +55°C
MountingPanel mounting, DIN rail mounting

Summary

INSTRUCTIONS

CIRCUIT SHIELD Type 87B

Identifies the specific model of the high impedance differential relay.

Catalog Series 419B

Specifies the catalog series for product identification and ordering.

INTRODUCTION

PRECAUTIONS

Essential safety guidelines and warnings for handling and applying the relay.

PLACING THE RELAY INTO SERVICE

RECEIVING, HANDLING, STORAGE

Guidelines for proper receipt, care, and storage of the relay.

INSTALLATION

Detailed steps and considerations for installing the relay.

Connections

Information on wiring and interconnecting the relay.

SETTINGS

How to configure voltage pickup and test/reset functions.

TRIMMER

Details on fine-tuning settings using the vernier trimmer.

Initial Check

Procedures for verifying wiring, power, and basic operation after installation.

SPECIFICATIONS

Input Circuit

Details on the relay's input impedance and sensitivity characteristics.

Tolerance

Specifies the acceptable tolerance for voltage pickup settings.

Operating Time

Information on the relay's total trip time and component timings.

Input Withstand

Ratings for continuous and short-term voltage withstand.

Frequency

Permissible operating frequencies for the relay.

Voltage Limiting

How the relay limits input voltage during faults.

Dielectric

Specifies the input-to-output isolation rating.

Control Power

Available control power voltages and their catalog numbers.

APPLICATION

Voltage Settings – External Faults

Guidance on setting voltage pickup above external fault voltages.

Withstand - Internal Faults

Information on the relay's thermal withstand and energy limits during internal faults.

Current Sensitivity - Internal Faults

How to determine minimum fault current for tripping based on relay burden and CTs.

Current Transformers – Wiring

Guidelines for selecting and wiring current transformers for optimal performance.

TESTING

MAINTENANCE AND RENEWAL PARTS

Guidance on maintenance, parts, and component replacement.

HIGH POTENTIAL TESTS

Warnings and procedures regarding high voltage insulation tests.

ACCEPTANCE TESTS

Factory tests and on-site checks to verify relay functionality.

Operational-Acceptance Test. Push-To-Test Button

Procedure for a basic operational test using the front panel button.

Bench Tests - Acceptance or Calibration

Detailed procedures for bench testing and calibrating the relay.

OBSOLETE RELAYS

419B00X4 Series Units

Information on obsoleted 419B series units and their replacements.

219B00X4 Series Units

Details on obsolete 219B series units and replacement with 419B series.

OTHER APPLICATIONS

Restricted Earth-Fault Protection

Diagram for ground fault protection of transformer/generator windings.