EasyManua.ls Logo

ABB E2N 12 User Manual

ABB E2N 12
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Emax
Installation, service and
maintenance instructions
for low voltage air circuit-breakers
Installation and service
instructions
1SDH000460R0002 L2778

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ABB E2N 12 and is the answer not in the manual?

ABB E2N 12 Specifications

General IconGeneral
BrandABB
ModelE2N 12
CategoryCircuit breakers
LanguageEnglish

Summary

1. Description

1.3.1 Circuit-breaker Rating Plate

Details the information found on the circuit-breaker's rating plate, including electrical specifications.

2. Checking on Receipt

Caution

Important safety precautions to follow during storage, including environmental and handling guidelines.

4. Installation

5. Electrical Connections

5.1 Connections to the Power Circuit

Details on connecting the circuit-breaker to the main power circuit via terminals and busbars.

5.2 Earthing

Instructions for connecting the earth terminals on both fixed and withdrawable circuit-breakers.

6. Putting into Service

6.1 General Procedures

General checks and procedures before putting the circuit-breaker into service, including connection tightness and voltage checks.

7. Instructions for Use

7.2 Circuit-breaker Closing and Opening Procedures

Step-by-step instructions for manual and electrical closing and opening operations.

7.3 Racking-in/out Operation

Detailed procedure for racking the circuit-breaker in and out of its fixed part, including safety precautions.

8. Maintenance

8.1 Warning

Safety warnings and preliminary procedures to be followed before performing any maintenance work.

8.3.2 General Inspection of the Circuit-breaker

Inspection checklist for operating mechanism, contacts, arcing chambers, and connections, including problem identification.

8.3.3 Checking Contact Wear

Procedure for checking and adjusting contact wear and gap, with specific steps for different Emax series.

9. Measures to be Taken for Any Operating Anomalies

Anomalies

Table listing possible causes and remedies for operating anomalies, linked to specific circuit-breaker states and LED indications.

11. Protection Releases - General Notes

11.1 Safety Notes

General safety warnings regarding the use and handling of the device, emphasizing qualified personnel and safe usage conditions.

12. SACE PR121/P Release - Identification

12.2.5 Protection Functions

Details the five independent protection functions, including RMS calculation and watchdog.

12.2.6 Description of the Protection Functions

Detailed description of each protection function (L, S, I, G, Iinst), including their curves and thermal memory.

12.4 Putting into Service

Steps for putting the PR121/P into service, including connections, tests, and initial settings.

12.7 Definition of Alarms and Signals for the PR121/P Unit

Details optical signals (LEDs) and their meanings for status indication and alarms.

12.7.2 Troubleshooting

Table of typical service conditions, possible causes, and suggested solutions for faults and malfunctions.

13. SACE PR122/P Release - Identification

13.2.9 Description of the Protection Functions

Detailed description of protection functions (L, S, G, U, OT, UV, OV, RV, RP, UF, OF) and their settings.

14.3 Putting into Service

Steps for putting the PR123/P into service, including connections, tests, and initial settings.

14.6 Definition of Alarms and Signals in the PR123/P Unit

Details optical signals (LEDs) and error messages for status indication and troubleshooting.

14.7 Troubleshooting PR123/P Unit

Table of typical service conditions, possible causes, and suggested solutions for faults.