3 Commissioning / 3.1 Oil supply
© Copyright 2018 . All rights reserved. HZTL2488_EN Revision E April 2018
Lubricating oil temperature at the inlet
CAUTION
Machine damage
If the oil temperature at the oil inlet exceeds the admissible range, this
may lead to engine damage.
u Observe oil temperature at the oil inlet according to the following
table.
Status for operation
Oil temperature at the
inlet
T
oil,inlet
[°C]
Permissible 30…90
Temporarily permissible (< 1h) -> alarm >90
Not permissible -> stop the engine >95
Not permissible -> Do not start the engine
(before starting: preheat the oil)
<30
Lubricating oil temperature at the outlet
The oil temperature at the outlet is mainly dependant on:
¡ Lubricating oil temperature and pressure at the oil inlet
¡ Engine load and turbocharger speed
¡ Exhaust gas temperature
The maximum admissible oil temperature at the outlet is listed in the fol-
lowing table. The specified oil outlet temperature is to be considered as
alarm value for the turbocharger operation and must be monitored ac-
cording to the current regulations.
Status for operation
Oil temperature at the outlet
T
oil,outlet
[°C]
Permissible 140
Temporarily permissible -> alarm >140
Not permissible -> stop the engine >160
If the turbocharger was operated for a longer period of time outside of
the admissible range, ABB Turbo Systems recommends to have the tur-
bocharger inspected by an ABB Turbocharging Service Station.