Table 198. Impedance functions, alternatives
Function Function
identification
Ordering no Position Available
qty
Selected
qty
Notes and rules
Note: One and only one of alternatives 1 to 6 must be selected. *) Selected qty = 0 for functions in unselected alternatives.
Alternative 1 Distance protection, quadrilateral
Distance protection zone, quadrilateral characteristic ZMQPDIS,
ZMQAPDIS
1MRK005907-AA 1 1-5 *)
Directional impedance quadrilateral ZDRDIR 1MRK005907-BA 2 1-2 *)
Phase selection, quadrilateral characteristic with fixed angle FDPSPDIS 1MRK005907-CA 3 2 *)
Alternative 2 Distance protection for series compensated lines, quadrilateral
Phase selection, quadrilateral characteristic with fixed angle FDPSPDIS 1MRK005907-CA 3 2 *)
Distance measuring zone, quadrilateral characteristic for series
compensated lines
ZMCPDIS,
ZMCAPDIS
1MRK005907-DA 4 1-6 *)
Directional impedance quadrilateral, including series
compensation
ZDSRDIR 1MRK005907-EA 5 1-2 *)
Alternative 3 Distance protection, mho (mho for phase - phase fault and mho in parallel with quad for earth fault)
Full-scheme distance protection, mho characteristic ZMHPDIS 1MRK005907-FA 6 1-5 *)
Full-scheme distance protection, quadrilateral for earth faults ZMMPDIS,
ZMMAPDIS
1MRK005907-GA 7 1-5 *)
Directional impedance element for mho characteristic ZDMRDIR 1MRK005907-HA 8 1-2 *)
Additional distance protection directional function for earth faults ZDARDIR 1MRK005907-KA 9 1-2 *)
Mho impedance supervision logic ZSMGAPC 1MRK005907-LB 10 1 *)
Faulty phase identification with load encroachment FMPSPDIS 1MRK005907-MA 11 2 *)
Alternative 4 Distance protection, quadrilateral with separate settings for PP and PE
Directional impedance quadrilateral ZDRDIR 1MRK005907-BA 2 1-2 *)
Distance measuring zone, quad characteristic separate Ph-Ph
and Ph-E settings
ZMRPDIS,
ZMRAPDIS
1MRK005907-NA 12 1-5 *)
Phase selection, quadrilateral characteristic with settable angle FRPSPDIS 1MRK005907-PA 13 2 *)
Alternative 5 High speed distance protection, quadrilateral and mho
High speed distance protection, quad and mho characteristic ZMFPDIS 1MRK005907-SC 14 1-2 *)
Alternative 6 High speed distance protection for series compensated lines, quadrilateral and mho
High speed distance protection for series comp. lines, quad and
mho characteristic
ZMFCPDIS 1MRK005907-RC 15 1-2 *)
Optional with alternative 1
Directional impedance element for mho characteristic ZDMRDIR 1MRK005907-HA 8 0-2
Optional with alternative 3
Phase selection, quadrilateral characteristic with fixed angle FDPSPDIS 1MRK005907-CA 3 0-2
Optional with alternatives 1, 2 and 4
Additional distance protection directional function for earth faults ZDARDIR 1MRK005907-KA 9 0-2
Faulty phase identification with load encroachment FMPSPDIS 1MRK005907-MA 11 0-2
Optional with alternatives 1, 2, 3 and 4
Phase preference logic PPLPHIZ 1MRK005908-DB 16 0-1
Optional with alternative 5 and 6
Phase preference logic PPL2PHIZ 1MRK005908-DC 17 0-1
Optional with any alternative
Power swing detection ZMRPSB 1MRK005907-UA 18 0-1
Automatic switch onto fault logic, voltage and current based ZCVPSOF 1MRK005908-AA 19 1
Power swing logic PSLPSCH 1MRK005907-VA 20 0-1
PoleSlip/Out-of-step protection PSPPPAM 1MRK005908-CB 21 0-2
Out-of-step protection OOSPPAM 1MRK005908-GA 22 0-1
Table 199. Current protection
Position
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
C 00 0 00 1 0 0 0 0 0
1MRK 506 372-BEN -
Line distance protection REL670 2.2
Product version: 2.2
ABB 129