EasyManua.ls Logo

ABB REL670 - Page 130

ABB REL670
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 200. Current functions
Function Function
identification
Ordering no Position Available
qty
Selected
qty
Notes and rules
Instantaneous phase overcurrent protection PHPIOC 1MRK005910-AD 1 0-3
Directional phase overcurrent protection, four steps OC4PTOC 1MRK005910-BC 2 0-3
Instantaneous residual overcurrent protection EFPIOC 1MRK005910-DD 4 0-3
Directional residual overcurrent protection, four steps EF4PTOC 1MRK005910-EE 5 0-3
Four step directional negative phase sequence overcurrent
protection
NS4PTOC 1MRK005910-FB 6 0-2
Sensitive directional residual overcurrent and power protection SDEPSDE 1MRK005910-GA 7 0-1
Thermal overload protection, one time constant, Celsius LCPTTR 1MRK005911-BA 8 0-2
Thermal overload protection, one time constant, Fahrenheit LFPTTR 1MRK005911-AA 9 0-2
Breaker failure protection CCRBRF 1MRK005910-LA 11 0-2
Stub protection STBPTOC 1MRK005910-NC 13 0-2
Pole discordance protection CCPDSC 1MRK005910-PA 14 0-2
Directional underpower protection GUPPDUP 1MRK005910-RA 15 0-2
Directional overpower protection GOPPDOP 1MRK005910-TA 16 0-2
Broken conductor check BRCPTOC 1MRK005910-SA 17 1
Voltage restrained overcurrent protection VRPVOC 1MRK005910-XA 21 0-3
Table 201. Voltage protection
Position 1 2 3 4 5 6 7 8
D 0 1
Table 202. Voltage functions
Function
Function
identification
Ordering no Position Available
qty
Selected
qty
Notes and rules
Two step undervoltage protection UV2PTUV 1MRK005912-AA 1 0-2
Two step overvoltage protection OV2PTOV 1MRK005912-BA 2 0-2
Two step residual overvoltage protection ROV2PTOV 1MRK005912-CC 3 0-2
Overexcitation protection OEXPVPH 1MRK005912-DA 4 0-1
Voltage differential protection VDCPTOV 1MRK005912-EA 5 0-2
Loss of voltage check LOVPTUV 1MRK005912-GA 7 1
Radial feeder protection PAPGAPC 1MRK005912-HA 8 0-1
Table 203. Frequency protection
Position
1 2 3 4
E 00
Table 204. Frequency functions
Function
Function
identification
Ordering no Position Available
qty
Selected
qty
Notes and rules
Underfrequency protection SAPTUF 1MRK005914-AC 1 0-6
Overfrequency protection SAPTOF 1MRK005914-BB 2 0-6
Rate-of-change of frequency protection SAPFRC 1MRK005914-CB 3 0-6
Table 205. Multipurpose protection
Position
1
F
Table 206. Multipurpose functions
Function
Function
identification
Ordering no Position Available
qty
Selected
qty
Notes and rules
General current and voltage protection CVGAPC 1MRK005915-AA 1 0-4
1MRK 506 372-BEN -
Line distance protection REL670 2.2
Product version: 2.2
130 ABB

Other manuals for ABB REL670

Related product manuals