EasyManua.ls Logo

ABB SPAU 140 C - Menu Chart

ABB SPAU 140 C
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Menu chart
Normal status, display off
Voltage U1
Voltage U2
Voltage U3
2
1
Second setting
value for U
2
1
Second setting
value for
21
Second setting
value for f
Actual frequency diff. value f
21
Main setting
value for t
check
Actual operating time t VC
2
1
Second setting
value for t
CB13
Actual operating time t CB13
2
1
2
1
Actual setting of function
switchgroup SGF
1
Main setting of
SGF checksum
Actual setting of blocking
switchgroup SGB
1
Main setting of
SGB checksum
2
Main setting
value for U
Main setting
value for
Main setting
value for f
Main setting
value for t
VC
Main setting
value for t
CB13
Second setting of
SGF checksum
2
21
Main setting
value for Umax
Actual voltage value Umax
SUBMENUS
FWD. STEP 1 s
REV. STEP 0.5 s
M
A
I
N
M
E
N
U
R
E
V.
S
T
E
P
.5
s
F
W
D.
S
T
E
P
1
s
MAIN MENU SUBMENUS
STEP 0.5 s PROGRAM 1 s
Second setting of
SGB checksum
1
2
Event (n-1) value of
U1
Event (n-2) value of
U1
Latest memorized, event (n)
value of U1
2
Event (n-1) value of
U3
Event (n-2) value of
U3
Latest memorized, event (n)
value of U3
1
2
2
3
1
23
4
1
2
4
Event (n-1)
value of
23
Event (n-2)
value of
23
1
2
Latest memorized, event (n)
value of
23
5
5
Fulfilled conditions
0
Communication rate
setting [Bd]
Loss of bus traffic time
counter 0..255 s
Relay unit identification
address for communication
A
1
2
A
1
Event (n-1) value of
U2
Event (n-2) value of
U2
Latest memorized, event (n)
value of U2
1
2
1
Latest memorized, event (n)
value of
13
Event (n-1)
value of
13
Event (n-2)
value of
13
6
6
1
2
Event (n-1)
value of f
3
Event (n-2)
value of f
3
Latest memorized, event (n)
value of f
3
1
Second setting
value for Umax
1
1
Voltage diff. U 13
Voltage diff. U 23
2
2
Frequency f 3
Actual voltage value Umin
Main setting
value for Umin
Second setting
value for Umin
Actual voltage diff. value U
Actual phase angle value
ϕ
ϕ
ϕ
Actual operating time t CB23
Second setting
value for t
CB23
Main setting
value for t
CB23
Actual setting of relay
switchgroup SGR
Main setting of
SGR checksum
Second setting of
SGR checksum
8
8
1
2
Event (n-1)
value of f
23
Event (n-2)
value of f
23
Latest memorized, event (n)
value of f
23
9
9
2
1
Event (n-1)
number of mode
Latest memorized, event (n)
number of mode
7
7
1
2
Event (n-1)
value of f
13
Event (n-2)
value of f
13
Latest memorized, event (n)
value of f
13
Event (n-2)
number of mode
000
TEST mode
11
Status of external relay
blocking/command sign.
ϕ
ϕ
ϕ
ϕ
ϕ
ϕ
Frequency diff.
f
13
Frequency diff.
f
23
Phase angle diff.
23
2
Phase angle diff.
13
2
ϕ
ϕ
Fig. 12. Main menu and submenus of the synchro-check module SPCU 3D45

Related product manuals