ABB SPCJ 4D29 User Manual

ABB SPCJ 4D29
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Ser.No.
SPAJ 142 C
aux
SPCJ 4D29
REGISTERS
OPER.IND.
0000
0
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
>
START
>
TRIP
>
>
TRIP
>
>
START
>
o
START
>
>
o
START
>
o
TRIP
>
>
o
TRIP
9
CBFP
9
0086A
I
I
I
I
I
I
I
I
80...265V
~
18...80V
2
5
U
f
n
= 50Hz
60Hz
RS 611 008 -
[
SGR
SGB
SGF
SPCJ 4D29
TRIP
PROGRAM
RESET
STEP
L1 L2 L3
0
IRF
3
>
I
I
I
II
I
>
n
I
I
/
k
s
>
t
]
n
>
>
I
I
/
s
>
>
[]
t
s
>
k
[]
t
n
0
>
I
I
/
s
>
>
o
t
[]
n
>
>
o
I
/
I
0012A
0
0
n
=
n
=
I
(
)
I
(
)
o
I
I
5A1A
1A0.2A
n
/
L3
n
/
L1
n
/
L2
max
(15min)
on
/
%
)(
>
%
)(
>>
()
>
o
%
(
o
)
%
>>
t
t
t
t
[]
[]
[]
[]
I
I
I
I
I
I
I
I
I
I
I
I
I
n
I
/
SPAJ 142 C
Overcurrent and earth-fault relay
User´s manual and Technical description
Question and Answer IconNeed help?

Do you have a question about the ABB SPCJ 4D29 and is the answer not in the manual?

ABB SPCJ 4D29 Specifications

General IconGeneral
BrandABB
ModelSPCJ 4D29
CategoryRelays
LanguageEnglish

Summary

SPAJ 142 C Overcurrent and Earth-Fault Relay Features

Description of Operation

Functionality of Overcurrent and Earth-Fault Stages

Explains how the overcurrent and earth-fault stages function and their characteristics.

Power Supply and Output Relay Module

Technical Data Summary

Overcurrent and Earth-Fault Unit Settings

Setting Ranges for Protection Stages

Details setting ranges and operations for low-set and high-set overcurrent and earth-fault stages.

Ordering Information and Options

Front Panel Controls and Display

Settings Configuration and Selector Switches

Example 1: Setting the Start Current

Manual Setting Procedure for I> Stage

Step-by-step guide for manually setting the start current for the I> stage.

Example 2: Setting Switchgroup Checksums

Recorded Information and Event Logging

Trip Test Functionality

Testing Output Signals and Relay Operation

Describes how to perform a trip test to activate output signals and verify relay operation.

Example 3: Forced Output Activation

Performing Forced Stage Activation Test

Step-by-step guide for forcing activation of output stages during a trip test.

Operation Indicators and Fault Codes

SPCJ 4D29 Relay Key Features

Overview of Module Capabilities

Lists the key features of the combined overcurrent and earth-fault relay module.

Description of Overcurrent Unit Function

Phase Overcurrent Stage Operations

Details the operation of the phase overcurrent unit, including low-set and high-set stages.

Description of Earth-Fault and CBFP Functions

Earth-Fault Unit and CBFP Operations

Explains the earth-fault unit and circuit breaker failure protection unit operations.

Front Panel Layout and Indicators

Settings Parameters and Ranges

List of Configurable Parameters

Lists all settable parameters, their ranges, and associated indicators.

Selector Switches - SGF1 Functions

Selector Switches - SGF2 Functions

Selector Switches - SGB Functions

Output Relay Matrix Configuration

Recorded Information in Registers

Time/Current Characteristics

Definite and Inverse Time Curves

Explains the definite and inverse time characteristics, including standard curves and formulas.

Detailed Technical Data

Stage-Specific Parameter Specifications

Lists specific technical data for overcurrent, earth-fault stages, and timing parameters.

Serial Communication Parameters and Event Codes

Data Communication Commands and Parameters

Fault Code Interpretation

Understanding and Handling Relay Faults

Lists common fault codes, their meanings, and procedures for handling faults.