32
ABB STOTZ-KONTAKT
2CDC 106 008 M5703
D
Auslösekennlinien
E
Tripping characteristics
F
Courbes de déclenchement
S
Utlösningskurvor
I
Caratteristiche di intervento
SP
Curvas características
de disparo
RUS
Характеристики
срабатывания
three
pole
4)
two pole
3)
Multiples of rated current
1)
Tripping time
2)
70.0 ... 88.0 ... 105.0 A
Tripping time
2)
Multiples of rated
current
1)
3 x Ie
6 x Ie
7.2 x Ie
min
three pole
4)
28.0 s
14.9 s
13.7 s
70.0 A
two pole
3)
16.8 s
10.0 s
9.1 s
max
three pole
4)
36.0 s
21.2 s
19.4 s
105.0 A
two pole
3)
20.5 s
12.6 s
11.7 s
three
pole
4)
two pole
3)
Multiples of rated current
1)
Tripping time
2)
95.0 ... 118.0 ... 140.0 A
Tripping time
2)
Multiples of rated
current
1)
3 x Ie
6 x Ie
7.2 x Ie
min
three pole
4)
26.6 s
16.0 s
14.8 s
95.0 A
two pole
3)
16.7 s
10.0 s
9.1 s
max
three pole
4)
36.5 s
22.4 s
20.5 s
140.0 A
two pole
3)
20.0 s
12.8 s
11.8 s
1) 2) 3) 4) 5)
Vielfaches vom Nennstrom Auslösezeit 2-polig 3-polig Sicherung
Multiple du courant de reglage Temps de déclenchement 2 broches 3 broches Fusible
Multipelfaktor för utlösningsström Utlösningstid 2-polig 3-polig Säkring
Multiplo della corrente di regolazione Tempo di apertura Bipolare Tripolare Fusibile
Múltiplos de la intensidad aplicada tiempo de disparo de 2 polos de 3 polos Fusible
Êîýôôèöèåíò òîêà óñòàâêè Âðåìÿ ñðàáàòûâàíèÿ Äâóõïîëþñíûé Òðåõïîëþñíûé Ïðåäîõðàíèòåëü
D
F
S
I
SP
RUS