5 Maintenance / 5.2 Cleaning the filter silencer
© Copyright 2018 . All rights reserved. HZTL2481_EN Revision C May 2018
Removing and cleaning the filter silencer
If provided
u Remove filter ring(81265).
u Rinse the filter ring(81265) using water with detergent additive or, if
it is heavily contaminated, soak and carefully push through. Rinse in
cold water. Avoid high mechanical stress (do not use a water jet).
NOTICE
The amount of filter ring(81265) contamination depends on the cleanli-
ness of the air that is drawn in. Clean filter ring after every 500 hours of
service or more frequently if necessary.
u Loosen the tension bands (81270) at the locks (81271) and remove
them along with the cover grids (81266) and connecting strips
(81268).
u Pull out insert units(E), bend open sheet-metal coverings(81137),
then take out absorption segments(81136).
u Clean the absorption segments (81136).
During cleaning, ensure that the absorption segments (81136) are
only cleaned with a mild jet of compressed air, soft brush or a damp
cloth. Otherwise there is a risk of damage or deformation.
NOTICE
Replace heavily contaminated absorption segments, filter ring and
damaged connecting strips with original parts from ABB Turbo Sys-
tems.
Fitting the filter silencer
u Assemble the insert units (E) by inserting the absorption seg-
ments(81136) into the sheet-metal coverings(81137).
u Bend the sheet-metal coverings back into the original shape.
u Insert the insert units (E) into the slot guides in the filter silencer body
(81135).
u Fit cover grids (81266) and connecting strips (81268) on the filter si-
lencer body (81135).
u Run tension bands (81270) through the eyelets of the connecting
strips.
u Tighten all tension bands at locks (81271).
If provided
u Fit filter ring (81265).
Page 47 / 136

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB TPL69-A Series and is the answer not in the manual?

ABB TPL69-A Series Specifications

General IconGeneral
BrandABB
ModelTPL69-A Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals