EasyManuals Logo

ABB VD4 Instruction Manual

ABB VD4
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
Instruction manual 534/01 | VD4 Vacuum-circuit-breaker 5
Contents Page
7 Commissioning/Operation 27
7.1 Note on safety at work 27
7.2 Preparatory activities 27
7.3 Movement of the withdrawable part 27
7.3.1 Manual insertion from the test/disconnected position to the service position 27
7.3.2 Manual withdrawable from the service position into the test/disconnected position 28
7.3.3 Motor-driven movement of the withdrawable part 28
7.3.4 Withdrawable from the test/disconnected position onto the service truck 28
7.3.5 Insertion from the service truck into the test/disconnected position 28
7.4 Operation of the circuit-breaker 28
7.4.1 Charging the spring energy storage mechanism 29
7.4.2 Closing and opening the circuit-breaker 29
8 Maintenance 31
8.1 General 31
8.1.1 Service-life 31
8.2 Inspection and functional testing 31
8.2.1 Switching device in general 31
8.2.2 Stored-energy spring mechanism 31
8.2.3 Breaker pole 32
8.2.4 Withdrawable assembly 32
8.3 Servicing 32
8.3.1 Switching devices in general 32
8.3.2 Stored-energy spring mechanism 32
8.3.3 Breaker pole 33
8.4 Repair 33
8.4.1 VD4 circuit-breaker run-on block 33
8.4.2 Replacement of circuit-breaker parts and accessories 33
8.4.3 Touch up of surfaces 33
8.4.4 Circuit-breakers in general 33
8.4.5 Replacement of contact systems 33
8.4.6 Replacement of withdrawable assembly 34
8.5 Testing withdrawable parts with a VD4 type circuit-breaker 34
8.5.1 Motor-driven withdrawable parts 34
8.5.2 Checking the correctness of dimensional settings 34
8.5.3 Checking auxiliary switch settings on type A withdrawable parts 34
8.5.4 Checking auxiliary switch settings on type B withdrawable parts 35
8.5.5 Checking the direction of rotation of the travel motors on motor-driven withdrawable parts 35
8.5.6 Testing of interlock conditions 35
8.6 Spare parts, auxiliary materials, lubricants 36
8.6.1 Spare parts 36
8.6.2 Auxiliary materials 38
9 Application of the X-ray regulations 42
10 Comparison of designations to VDE-DIN 40719 Part 2 and IEC 61346-1/IEC 61346-2 42

Table of Contents

Other manuals for ABB VD4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB VD4 and is the answer not in the manual?

ABB VD4 Specifications

General IconGeneral
TypeVacuum Circuit Breaker
Rated VoltageUp to 36 kV
Rated Short-Circuit Breaking CurrentUp to 63 kA
Frequency50/60 Hz
StandardsIEC 62271-100
ApplicationMedium voltage power distribution
Rated Short-Time Withstand CurrentUp to 63 kA for 3 seconds
Mechanical LifeUp to 30, 000 operations
InstallationFixed / Withdrawable
Operating MechanismSpring-operated
Rated Current630 A / 800 A / 1250 A / 1600 A / 2000 A / 2500 A / 3150 A / 4000 A
Electrical LifeUp to 10, 000 operations at rated current
Control Voltage24 V DC, 48 V DC, 110 V DC, 220 V DC, 110 V AC, 230 V AC

Related product manuals