EasyManua.ls Logo

ABL eMH1 WALLBOX - Error Sequence F3: RCM14 or DC Fault

ABL eMH1 WALLBOX
71 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
LED presets
Only green LEDs
Only blue LEDs
Both LEDs
6. ERROR MESSAGES
Sequence F3
The automatic self-test of the internal RCM14 has returned an error, or a DC fault current
has been detected in connection with the vehicle
The green and blue LEDs alternately flash twice each
200ms 200ms 200ms 200ms200ms200ms200ms200ms200ms200ms
1 If the error is occurring for the first time, the
charging procedure is interrupted for 30 seconds
and then restarted automatically. The charging
procedure is cancelled. A new charging procedure
is only possible after disconnecting the vehicle from
the Wallbox.
2 Take the Wallbox out of operation permanently.
Shutdown: p. 54
Check the vehicle for electrical faults in the
charging system. Contact a qualified specialist
repairer for this purpose.
When error messages are displayed
continuously,
take the Wallbox out of operation
permanently.
Shutdown: p. 54
Contact the specialist electrical
contractor
Should the problem persist,
please contact ABL technical support.
Technical support: p. 70