Page 21AN120076.000_EN
3. After an incorrect PIN code or CODE no. has been
entered four times, the unit is locked out for all furt-
her PIN and CODE entries.
If the unit is locked out and you attempt to enter a
PIN or CODE number, ”no” appears on t he display.
A locked out unit can only be unlocked by ABUS.
However, the unit will still function correctly.
[no]
4. When you leave the menu level, the current soft-
ware version is displayed.
_________________________________
5. Table 1: Measuring ranges of current measurement modules
Current measurement module
Measuring
range
In
[A]
Current measure-
ment module
Correction
factor
AN Remarks
0
3
115
19683
I
8
306
9743
II
16
613
9744
III
23
873
9745
IV
36
1381
9746
V
60
2344
9747
VI
136
5169
19682