Page 27AN120076.000_EN
13 Current measurement modules for GM hoist motors
Current hoist designs
Voltage range 3Y
(380 415 V; 50 Hz. // 440 480 V; 60 Hz.)
Hoist motor Current measuing module
No.
Hoist
Type
Motor
Type
(Input
P1.1)
P
[KW]
at 50 Hz.
12 / 2 pole
In
[A]
12 / 2 pole
R I nput for
P1.2 (in Ohms)
12/2–pole
Measu-
ring
range
In
[A]
Current
measuing
module
Correction
factor
AN Remarks
1 Non–ABUS motor,
old ABUS motor F6 or
motor with voltage other
than 400 V
0
(see nameplate) (see nameplate) measure and enter
in P1.2
2 GM 800 L.4
1
0,28 / 1,9 1,8 / 5,0 28,2 / 4,06
I
8
306
9743
3 GM 800 H.4
2
0,45 / 3,2 3,1 / 7,2 21,0 / 2,16
I
8
306
9743
4 GM 800 U .4
0
0,55 / 4,0 4,0 / 8,5 17,6 / 1,76
I
8
306
9743
5 GM 1000 L.6
3
0,45 / 3,0 2,4 / 7,7 18,6 / 2,16
I
8
306
9743
6 GM 1000 H.6
4
0,80 / 4,9 4,4 / 11,2 11,2 / 1,3
II
16
613
9744
7 GM 1000 U .6
0
0,90 / 6,0 4,6 / 13,0 10,2 / 1,05
II
16
613
9744
8 GM 2000 L.3
5
0,80 / 4,9 4,4 / 11,2 11,2 / 1,3
II
16
613
9744
9 GM 2000 H.3
6
1,1 / 7,6 5,1 / 15,9 8,65 / 0,79
II
16
613
9744
10 GM 3000 L.4
7
1,2 / 7,4 5,6 / 15,3 10,4 / 1,0
II
16
613
9744
11 GM 3000 H.4
8
1,9 / 12,3 8,2 / 22,9 6,65 / 0,51
III
23
873
9745
12 GM 5000 L.3
9
1,9 / 12,3 8,2 / 22,9 6,65 / 0,51
III
23
873
9745