Page 29AN120076.000_EN
Voltage range 3
(220 240 V; 50 Hz. // 255 280 V; 60 Hz.)
Hoist motor Current measuing module
No.
Hoist
Type
Motor
Type
(Input
P1.1)
P
[KW]
at 50 Hz.
12 / 2 pole
In
[A]
12 / 2 pole
R I nput for
P1.2 (in Ohms)
12/2–pole
Measu-
ring
range
In
[A]
Current
measuing
module
Correction
factor
AN Remarks
1 Non–ABUS motor,
old ABUS motor F6
0
(see nameplate) (see nameplate) measure and enter
in P1.2
2 GM 800 L.4
0
0,28 / 1,9 3,1 / 8,7 4,7 / 0,677
I
8
306
9743
3 GM 800 H.4
0
0,45 / 3,2 5,4 / 12,5 7 / 0,72
II
16
613
9744
4 GM 800 U .4
0
0,55 / 4,0 6,9 / 14,7 5,86 / 0,585
II
16
613
9744
5 GM 1000 L.6
0
0,45 / 3,0 4,2 / 12,8 6,15 / 0,707
II
16
613
9744
6 GM 1000 H.6
0
0,80 / 4,9 7,6 / 19,4 3,70 / 0,43
III
23
873
9745
7 GM 1000 U .6
0
0,90 / 6,0 8,0 / 22,5 3,4 / 0,35
III
23
873
9745
8 GM 2000 L.3
0
0,80 / 4,9 7,6 / 19,4 3,70 / 0,43
III
23
873
9745
9 GM 2000 H.3
0
1,1 / 7,6 8,8 / 27,5 2,9 / 0,26
IV
36
1381
9746
10 GM 3000 L.4
0
1,2 / 7,4 9,7 / 26,5 3,45 / 0,33
IV
36
1381
9746
11 GM 3000 H.4
0
1,9 / 12,3 14,2 / 39,7 2,22 / 0,17
IV
36
1381
9746
12 GM 5000 L.3
0
1,9 / 12,3 14,2 / 39,7 2,22 / 0,17
IV
36
1381
9746