Voltage range 1
(175 195 V; 50 Hz. // 208 230 V; 60 Hz.)
Hoist motor Current measuing module
No.
Hoist
Type
Motor
Type
(Input
P1.1)
P
[KW]
at 60 Hz.
12 / 2 pole
In
[A]
12 / 2 pole
R I nput for
P1.2 (in Ohms)
12/2–pole
Meßbe–
reich
In
[A]
Current
measuing
module
Correction
factor
AN Remarks
13 GM 5000 H.3
0
3,5 / 22,6 26,5 / 74 0,866 / 0,05
VI
136
5169
14 GM 6000 L 3
0
3,5 / 22,6 26,5 / 74 0,866 / 0,05
VI
136
5169
15 Reserve
16 GM 7000 L
0
2,9 / 19,2 20,1 / 54 0,93 / 0,09
V
60
2344
9747 1 motor
17 GM 7000 H
0
5,8 / 38,4 40,2 / 108 0,465 / 0,045
VI
136
5169
19682 2 motors
18 GM 7000 M
0
3,6 / 24 25 / 73 0,866 / 0,05
VI
136
5169
19682 1 motor
19 GM 7000 U
0
7,2 / 48 50 / 146 0,433 / 0,025
VI
136
5169
19682 2 motors
20
R measured 3*Rmeasured [U–V] R measured
R Input = ––––––––––––– R phase = –––––––––––––––––– for 2 motors R Input = –––––––––––––
22 4