Functional principle and features
13
Sensor type
Electrochemical
Sensor lifespan
7 years
Sensor range
0 to 1,000 ppm
Detection range
max. 60
Power consumption
< 80 µA (Ø standby) || < 25 mA (Ø alarm)
Operating temperature
0° to 40° C
Humidity
30% to 95% (non-condensing)
Sound pressure
> 85 dB (A)@1 m (3.5 +/- 0.5 kHz pulsing)
Alarm muting
5 minutes
Installation location
Wall
Functional principle and features
According to EN 50291, the COWM300 ABUS CO alarm is
designed and approved exclusively for detecting CO (carbon
monoxide) in private homes.
Application in industrial facilities, offices, boats, caravans or
mobile homes is therefore not permitted.