38
Status LED on the Secvest IP
Green LED (“Power” LED) for monitoring the power supply
•Permanentlylit:powersupplyisOK
•Flashingwith1Hz:mainspowersupplyfailure;isonlyindicatedif
a backup battery is in use.
Red LED (“Trouble” LED) for indicating faults
•O:nofaults
•Flashingwith1Hz:supervisionfault(detectorordeviceisindicated
by the channel LED ashing with 1 Hz. If only this LED ashes, this
indicates that the control panel itself has been tampered with).
•Permanentlylit:indicatesjamming.
Blue LEDs (“Channel” LEDs) for detector status display
•O:detectorOK(closed)
•Permanentlylit:detectorisopen,orhastriggered(open),
operating units are lit briey signalising that a radio signal has
been sent.
•Flashingwith5Hz:lowbattery
•Flashingwith1Hz:tamperingwithdetectorordevice
Bottom blue LED lights up: indicates that this refers to the second
caption level. (i.e. channels 8-14)