43
Select the preferred language.
Enter admin in the User Name eld together
with 12345678 for the Password and press the
Login button.
The rst time you access your Secvest IP, the
overview menu will be displayed.
In the Inputs area, you will see an overview of
the state of your three radio zones (1) and three
virtual IP zones (2). The colour of the respective
LED signalises the current status of the input.
Green means that the status of the detector group
(orIPzone)isOK;redmeansthatadetectorin
the detector group (or IP zone) has triggered or
opened and grey indicates a disabled/hidden
zone or a zone without a connected detector.
The Outputs area lets you switch the two radio
switching outputs (1 and 2) and the relay
output(3). You can see the actual status at the
same time. If the LED on the button is white
and the lettering has a blue background, this
indicates that the output is currently switched
on (see: (1)).