Installation and start-up
12 EN
DIP switch layout
6. Adjust the DIP switch as required.
Factory/defa
ult setting*
Role
OFF
ON
1
STATUS LED
Permanent status LEDs
The status of the sub-
areas is only displayed for
a few seconds during
operation*
Permanent status LEDs
2
BACK COMP
Backward compatibility
FUAA50xxx*
All versions of firmware
Works in same way as
FUBE50000 (without
rolling code)
FU80xx
Works in same way as
FU8110
3
BATT MODE
Battery operation
Power supply unit
operation
(incl. batteries)*
Battery operation
(without power supply unit)
Suppresses the status
message "Ext. PSU error"
on the alarm control panel
4
INFO TONES
Info and alarm tone
sounds on the control
panel
No info or alarm tone
sounds on the control
panel*
Info and alarm tone
sounds on the control
panel*
5
KEY TONES
Keypad tones
Keypad tones deactivated*
Keypad tones activated*
6
PROX ENB
Chip key reader
Chip key reader
deactivated
Chip key reader activated*
7
KEY LED
Permanent keypad
lighting
Keypad lighting during
operation only*
(times out after 15
seconds)
Permanent keypad lighting
8
NU
Rolling code
WITHOUT
Rolling code
Compatibility as per DIP-
2
WITH
rolling code*
Compatible with Secvest
FUAA50xxx firmware
>=v2.00.03
DIP-2 without effect