– 26 –
Technical data
• Power supply DC 3 V Lithium Battery (built-in)
• Smoke detection photoelectric reection
• Visual operating display LED ashes approx. every 6 minutes
• Electric consumption 9.8 μA (Ø standby) || 80 mA (Ø alarm)
• Operating temperature 0° to 45° C
• Air humidity 10 % to 90 % (non-condensing)
• Sound pressure > 85 dB (A)@3 m
• Alarm mute mode 9 minutes
• Detection range max. 40 m² within a single room
• Installation location ceiling (internal rooms only)
Functions and technical features
• The smoke alarm does not detect gases, vapours, heat and fire/flames!
• It is possible that people with limited hearing may not hear the alarm!
For such cases special alarms with optical signalling are available.
• Especially high electromagnetic radiation may affect unit operation. Therefore, do
not install the alarm near devices which emit electromagnetic radiation or close
to magnets.
• This smoke alarm works according to the principles of optics (photoelectric
reflection) and contains a measuring chamber in which penetrating smoke
particles are measured.
Safety information Technical data