12
17 1
Power report
(Threshold
value in percent)
10
The threshold value serves as an additional
condition for the time-based report.
If the threshold value was not exceeded, the
time-based report is not sent.
The value 0 deactivates the power report
threshold.
Adjustable from 0 – 127 in Watt
(Hexadecimal: 0x00 – 0x7F)
100 1 Reset 101 – 104
-
84 = Resets parameter 101 - 104 to
factory setting.
101 4
Power report
(Time)
600
The interval time of the power report (W).
The value 0 disables the report.
Adjustable from 5 - 2678400 in seconds
(Hexadecimal: 0x00 - 0x28DE80)
102 4
Consumption
report
(Time)
3600
The interval time of the consumption report
(kWh).
The value 0 disables the report.
Adjustable from 5 - 2678400 in seconds
(Hexadecimal: 0x00 - 0x28DE80)
103 4
Voltage report
(Time)
0
The interval time of the voltage report (V).
The value 0 disables the report.
Adjustable from 5 - 2678400 in seconds
(Hexadecimal: 0x00 - 0x28DE80)
104 4
Current report
(Time)
0
The interval time of the current report (A).
The value 0 disables the report.
Adjustable from 5 - 2678400 in seconds
(Hexadecimal: 0x00 - 0x28DE80)
254 1
Enable / Disable
Configuration
0
Enables / Disables the configuration.
0 = Configuration is enabled
1 = Configuration is disabled
(Hexadecimal: 0x00 - 0x01)