11
3.2. Overview Configuration Parameter
Z-Wave products can be used in the network immediately after inclusion. Through configuration
settings, however, the behaviour of the device can be adapted even better to the requirements of the
application and additional functions can be activated.
Para-
meter
Byte-
size
Funktion
Default-Value
(Decimal)
Description
1 1
Overvoltage
protection
1
Enable / Disable overvoltage protection.
0 = Disabled
1 = Enabled
(Hexadecimal: 0x00 – 0x01)
2 1
Device status
after power
failure
0
Set which device status should be present after
a power failure.
0 = Status before power failure
1 = Status “on”
2 = Status “off”
(Hexadezimal: 0x00 – 0x02)
3 1
Device status
report
1
Device status report when device status
changes.
0 = Disabled
1 = Send report
2 = Send report only with manual change
(Hexadezimal: 0x00 – 0x02)
4 1
LED indicator
0
Behaviour of the LED display with device status
"On".
0 = LED is permanently active with
device status "On
1 = LED is active for 5 seconds when
changing to device status "On" and then
extinguishes
(Hexadezimal: 0x00 – 0x01)
16 2
Power report
(Threshold)
50
The threshold value serves as an additional
condition for the time-based report.
If the threshold value was not exceeded, the
time-based report is not sent.
The value 0 deactivates the power report
threshold.
Adjustable from 0 – 65535 in Watt
(Hexadecimal: 0x00 – 0xFFFF)