EasyManua.ls Logo

Abus SHMK10000 - Unterstützte Command Classes; 6 Technical Specifications

Abus SHMK10000
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
English
2- When the sensor detects status change between close
door and open door, the device will be triggered.
Group 5
0x05
Root Device group(Notification)
1-Binary Sensor reports the removed status of door sensor.
2- When the sensor detects status change of tamper, the
device will be triggered.
5.2. Supported Command Classes
1 Z-Wave plus Info Version 2
2 Notification Version 8
3 Association Version 2
4 Association Group Info Version 1
5 Transport Service Version 2
6 Version Version 3
7 Manufacturer Specific Version 2
8 Device Reset Locally Version 1
9 Powerlevel Version 1
10 Battery Version 1
11 Security 2 Version 1
12 Supervision Version 1
13 Wake Up Version 2
6. Technical Specifications
Parameters
Unit
SHMK10000
Dimensions
mm
72 x 21 x 26 (Sensor) / 35 x 11 x 13 (Magnet)
Weight
g
45
Operating Temperature
°C
0 40
Max. Humidity
%
95
IP Class
20
Radio frequency
MHz
868,42 (Z-Wave PLUS, Europe)
Modulation
FSK/GFSK
Transmission power
db
< 4,5
Power supply
3 V DC
Battery type
CR2
Power consumption standby
mA
0,005
Power consumption trigger
mA
38
Battery-life
3 Years (10 triggers per day)
Range (open field)
m
100
Range (building)
m
20, related to material of walls
Tamper protection
Yes
Firmware updateable
No
Support Z-Wave Beaming
No
SmartStart supported
No
Z-Wave Network Security
Yes
Z-Wave AES-128 Security
Yes
Z-Wave Plus
Yes

Other manuals for Abus SHMK10000

Related product manuals