ELECTRICAL INSTALLATION INSTRUCTIONS
All electrical wiring must be performed by a qualified, licensed
electrician in order to meet NEC, (National Electrical Code)
state and local codes.
This unit is a Permanently Connected Equipment Assembly
with Pump(s), Heater, Blower and Control.
All wiring must be shielded by a ground metal conduit. The
conduit must terminate at the electrical access compartment
either from the bottom of the spa or through a hole in the side
paneling of the spa.
The lines carrying power to the spa must be dedicated and
should not be shared with other appliances. Use copper wiring
only. Use #6 AWG conductors.
A pressure wire connector is provided on this unit to connect
a minimum 8 AWG (8.4mm2) solid copper conductor between
this unit and any metal equipment, metal enclosures of
electrical equipment, metal pipe, or conduit within 5 feet
(1.5m) of the unit.
The electrical supply for this unit must include a suitably rated
GFCI/CIRCUIT BREAKER to open all ungrounded supply
conductors to comply with Section 422-20 of the National
Electric Code.
A quick disconnect marked OFF must be readily accessible to
the tub occupant, installed at least 5 feet (1m) from the tub.
All electrical wiring lines must originate from the main
electrical panel and terminate, hard wired, into the electrical
wiring compartment. The use of extension cords, or plug type
termination is expressly prohibited and voids the warranty.
Minimum supply conductor ampacity must be 125 percent of
the current rating stated on the ID label affixed to, equipment
control enclosure.