You should also have a spa userās manual which
explains how to care for your spa. Please read and
follow all instructions in your spa userās manual.
Maintaining the proper levels of pH and the sanitizer
will extend the life of your spa equipment. Improper
chemical levels in the spa are sure to cause premature
heater failure as well as failure of other components
in the system. Failures caused by chemical imbalance
are not covered by warranty.
NO
Check power at Heater ELEMENT. If no power one or more heater relay(s) is NOT -- closing.
Replace PCBoard.
OVERHEAT ERROR CODES ( OH or HLEr) but spa water temperature is not.
Allow enough time for the sensors to cool down. Then clear the error code by pressing the SET button.
1-Turn temperature down to lowest setting & press the SET key
2- Press SET a second time and allow the low speed Jets to run for 2-3 minutes
3-Is temperature reading dropping? Does it match the thermometer reading in the spa ?
4-If YES . there is flow restriction. Clean / inspect or remove filter cartridge. Or secondary bypass intake to the pump is
blocked or not installed, or pump is air locked.
5-Raise the temperature setting 4 degrees above water temperature. Average heat gain is about 30 minutes. If there is rapid
heat gain go back to step #4.
QRC- 215A