9
FOR 220 V 50 or 60Hz applications
Product No. 6700952 should be ordered.
6700952 includes a 2 KVA 220 Volt Step
Down to 110 volt 50/60 Hz transformer
which is prewired.
The wiring diagram is shown in FIG. 8.
The power cord has no connector. A
connector which is appropriate for your
locality and 220 volt, 8 amp application
should be installed.
ASSEMBLY INSTRUCTIONS (Continued)
FIG. 8
IMPORTANT GROUNDING INSTRUCTIONS
In case of a malfunction of breakdown, grounding reduces the risk of electrical shock by providing a path
of least resistance for electrical current.
This Grinder has an electrical cord with an equipment grounding conductor and a grounding plug. The
plug must be plugged into a matching outlet that is properly installed and grounded according to all local
or other appropriate electrical codes and ordinances.
Before plugging in the Grinder, make sure it will be connected to a supply circuit protected by a properly-
sized circuit breaker or fuse. SEE SERIAL NUMBER PLATE FOR FULL LOAD AMP RATING OF YOUR
MACHINE.
Never modify the plug provided with the machine--if it won't fit the outlet, have a proper outlet and circuit
installed by a qualified electrician.
ALWAYS PROVIDE A PROPER ELECTRICAL GROUND FOR YOUR
MACHINE. AN IMPROPER CONNECTION CAN CAUSE A DANGEROUS
ELECTRICAL SHOCK. IF YOU ARE UNSURE OF THE PROPER
ELECTRICAL GROUNDING PROCEDURE, CONTACT A QUALIFIED
ELECTRICIAN.
USE ONLY A QUALIFIED
ELECTRICIAN TO COMPLETE
THE INSTALLATION.
CHARGING THE UNINTERUPTABLE POWER SUPPLY
The Uninteruptable Power Supply (UPS) comes from the supplier with no
charge. When the machine is ready for operation, plug it in and turn on the
UPS. The battery must charge for a minimum of 24 hours. For UPS functions,
refer to the separate manual supplied with the grinder.
THE UPS WILL NOT FUNCTION PROPERLY IF THERE IS INSUFFICIENT
POWER TO THE MACHINE. INSUFFICIENT POWER MAY ALLOW THE
BEDKNIFE TO SLIP OR MOVE ON THE MAGNETS WHILE GRINDING. SEE
PREVIOUS PAGE FOR POWER REQUIREMENTS.