DC Inverter U-match Series for R410A Unitary Split Air Conditioner
18
2) The whole pipeline should be wound together to avoid water returning
to the room.
3) Use saddles to fix the whole pipeline onto the wall.
3.3 Electrical Installation
3.3.1 Requirement and Notice on Electrical Installation
The electrical installation for the air conditioner should observe the following
requirements:
. The electrical installation must be conducted by professionals in compliance
with local laws and regulations and the instructions in this manual. Never
extend the power cords. The electric circuit must be equipped with a circuit
breaker and air switch both with sufficient capacity.
. The unit’s operating power must be within the nominal range stated in the
instruction manual. Use a specialized power circuit for the air conditioner. Do
not draw power from another power circuit.
. The air conditioner circuit should be at least 1.5m away from any inflammable
surface.
. The external power cords, the thermostat wires and outdoor unit must be
effectively fixed.
. The external power cords, the thermostat wires and outdoor unit can’t directly
contact any hot objects. For example: they must not contact chimney pipes,
warm gas pipes or other hot objects.
. The external power cords, and the thermostat wires and outdoor unit must not
be squeezed. Never pull, stretch or bend the wires.