Improper installation, adjustment, or service can cause explosion, fire, or electrical shock. Consult qualified personnel.
Warning about electrical shock; disconnect power before installation/servicing. Lock out and tag switches.
Installation must follow manual, NEC/CEC, and national wiring rules. Refrigerant circuit work requires certification.
Warnings regarding using correct accessories, secure installation, independent power circuits, and cleaning precautions.
Specifies clearance dimensions (a, b, c, d, e) for installing a single outdoor unit.
Specifies clearance dimensions for installing multiple outdoor units side-by-side.
Specifies clearance dimensions for installing outdoor units in rows.
Specifies clearance dimensions for installing outdoor units one above another.
Instructions and requirements for installing connection pipes, including matching sizes and avoiding damage.
Guidance on connecting pipes, bending, tightening, and insulating to prevent damage and leakage.
Instructions for connecting pipes using spanner and torque wrench, including oil application and insulation.
Procedures for vacuum pumping and leak detection of the connection pipes.
Steps for vacuum pumping, including closing valves, connecting hoses, and starting the vacuum pump.
Details on evacuation duration, pressure verification, balancing pressure, and closing valves.
Table for additional refrigerant amounts based on pipe length for FXD-ACD36 and FXD-ACD60.
Electrical installation must comply with laws, use professionals, specialized circuits, and maintain safe distances.
Electrical installation must comply with laws, use professionals, specialized circuits, and maintain safe distances.
Rules for power cords, thermostat wires, fixing, avoiding hot objects, not squeezing wires, and grounding.
Instructions for connecting solid and stranded wires to the terminal board.
Details on preparing solid and stranded wires, using terminals, and connecting thermostat wires and power cords.
Warnings about checking power status, wrong connections, firm wiring, and ground wire connection.
Wiring diagram and notes for connecting FXD-ACD36 outdoor unit power and thermostat wires.
Wiring diagram and notes for connecting FXD-ACD60 outdoor unit power and thermostat wires.
List of checks to perform after installation and potential consequences of improper installation.
List of checks to perform after installation and potential consequences of improper installation.
Checks for wire compliance, air path obstruction, and refrigerant charging amount recording.
Procedures for powering on, testing operation, preheating, and handling liquid shock sounds.
Steps to take before powering on, including checking installation completion, circuits, valves, and internal cleanliness.
Procedures for powering on, testing operation, preheating, and handling liquid shock sounds.
List of error codes displayed on the outdoor unit LED and their corresponding meanings.
Detailed explanations of various error codes (E1, E3, E4, F2, etc.) related to compressor, sensors, and protection.