23833A414 (Rev. 01/03/17) Bag #23834A018
Model
ESP-75A 3/4 HP 4039145
ESP-100A 1 HP 4039152
ESP-150A 1-1/2 HP 4039160
ESP-200A 2 HP 4063558
CONSUMER HOT-LINE: 1-800-422-1551
Monday-Friday 7 AM to 5 PM CST
INSTALLATION MANUAL
Lawn Sprinkler for Inground
Sprinkler Systems
WARRANTY: Product defects covered for 12 months from date of purchase.
Receipt is required for warranty claim.

Questions and Answers

  • H
    hernandezjohnAug 9, 2025
    Why Ace Irrigation System pump does not deliver rated capacity?
    • M
      Megan MartinAug 9, 2025
      Several factors could be at play. It might be due to insufficient submergence of the suction pipe; ensure it's at least 3 feet below the water level. Verify that the pump's voltage matches the power supply voltage. Check the valve, suction piping, foot valve, or well point for any issues. The discharge system head might be too great, or the well depth could exceed the pump's capacity. The pump flow might be greater than the well flow capability. Ensure all connections are airtight and that the suction pipe isn't too small; it should be a 1-1/2" pipe.
  • H
    Heather BergerAug 20, 2025
    What to do if Ace Irrigation System pump will not prime?
    • J
      Jennifer JonesAug 20, 2025
      If your pump isn't priming, try these steps: Stop the motor, remove the 1-1/2" pipe plug, and fill the case with water. Ensure the pump voltage matches the power supply voltage. Inspect the valve, suction piping, foot valve, or well point. The foot valve might be sitting in sand or mud, stuck shut, or leaking. Check all connections to ensure they are airtight and check for a leaky shaft seal.
  • C
    Cynthia EscobarAug 28, 2025
    Why Ace Irrigation System pump loses prime after starting?
    • J
      Justin FernandezAug 28, 2025
      The issue might be caused by several reasons. The suction pipe might not be submerged enough; it needs to be at least 3 feet below the water level. The well depth might exceed the pump's capability, or the pump flow might be greater than the well's flow capability. Make sure that all connections are airtight.

Summary

General Safety

Important Safety Instructions

Crucial safety guidelines to prevent injury and property damage before installation.

Installation Procedures

Well Depth and Piping Guidelines

Measuring well depth and proper piping techniques for pump systems.

Pump Specifications and Capacities

Technical details including fuse, breaker, wire selection, and pump performance data.

Inground Pump Installation

Steps, materials, and tools for installing inground lawn sprinkler pumps.

Well Point Pump Installation

Specific instructions for installing pumps with well points.

Troubleshooting

Pump Disassembly and Repair

Warranty Information

Ace ESP-100A 1 HP Specifications

General IconGeneral
Power1 HP
MaterialCast Iron
Housing MaterialCast Iron
PhaseSingle
Inlet Size1 inch