EasyManua.ls Logo

Ace ESP-75A 3/4 HP - User Manual

Ace ESP-75A 3/4 HP
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
23833A414 (Rev. 01/03/17) Bag #23834A018
Model
ESP-75A 3/4 HP 4039145
ESP-100A 1 HP 4039152
ESP-150A 1-1/2 HP 4039160
ESP-200A 2 HP 4063558
CONSUMER HOT-LINE: 1-800-422-1551
Monday-Friday 7 AM to 5 PM CST
INSTALLATION MANUAL
Lawn Sprinkler for Inground
Sprinkler Systems
WARRANTY: Product defects covered for 12 months from date of purchase.
Receipt is required for warranty claim.

Questions and Answers

  • R
    Ricardo WalkerAug 5, 2025
    Why Ace Irrigation System pump does not deliver rated capacity?
    • J
      Joy KhanAug 6, 2025
      Several factors could be at play. It might be due to insufficient submergence of the suction pipe; ensure it's at least 3 feet below the water level. Verify that the pump's voltage matches the power supply voltage. Check the valve, suction piping, foot valve, or well point for any issues. The discharge system head might be too great, or the well depth could exceed the pump's capacity. The pump flow might be greater than the well flow capability. Ensure all connections are airtight and that the suction pipe isn't too small; it should be a 1-1/2" pipe.
  • R
    Ronnie BurgessAug 14, 2025
    What to do if Ace Irrigation System pump will not prime?
    • B
      byrdveronicaAug 14, 2025
      If your pump isn't priming, try these steps: Stop the motor, remove the 1-1/2" pipe plug, and fill the case with water. Ensure the pump voltage matches the power supply voltage. Inspect the valve, suction piping, foot valve, or well point. The foot valve might be sitting in sand or mud, stuck shut, or leaking. Check all connections to ensure they are airtight and check for a leaky shaft seal.
  • A
    Anthony MckeeAug 25, 2025
    Why Ace Irrigation System pump loses prime after starting?
    • J
      Jerry WrightAug 25, 2025
      The issue might be caused by several reasons. The suction pipe might not be submerged enough; it needs to be at least 3 feet below the water level. The well depth might exceed the pump's capability, or the pump flow might be greater than the well's flow capability. Make sure that all connections are airtight.

Summary

General Safety

IMPORTANT INSTRUCTIONS BEFORE INSTALLATION

Crucial safety guidelines to prevent injury and property damage during pump installation.

Installation Guide

Finding the Depth of Your Well

Procedure to measure well depth for optimal pump operation and prevent hindrance.

Piping Requirements

Guidelines for selecting and installing piping, emphasizing airtightness for pump function.

Pump Specifications

Fuse;Breaker & Wire Selection Guide

Details on fuse/breaker, wire gauge, and pump capacities based on model and voltage.

Pump Capacities

Table detailing pump flow rates (GPM) at various pressures and suction lifts.

Inground Pump Installation

General Materials and Tools Required

Lists essential materials and tools needed for inground pump installation.

Installation Steps Overview

Outlines the process for installing inground lawn sprinkler pumps.

Well Point Pump Installation

Multiple Well Points and Draining

Guidance on connecting multiple well points and draining the pump for servicing or winter.

Troubleshooting

Troubleshooting Checklist

A list of common pump problems and their potential causes for diagnosis and resolution.

Pump Disassembly and Repair Kits

Repair Kit Information

Details on available repair kits for pump components like diffusers and seals.

Warranty Information

Limited Warranty Terms and Conditions

Details on the 12-month limited warranty, coverage, exclusions, and claim procedures.

Ace ESP-75A 3/4 HP Specifications

General IconGeneral
Power3/4 HP
Voltage115/230V
Max Flow Rate75 GPM
Max Pressure50 PSI
Housing MaterialCast Iron

Related product manuals