23833A414 (Rev. 01/03/17) Bag #23834A018
Model
ESP-75A 3/4 HP 4039145
ESP-100A 1 HP 4039152
ESP-150A 1-1/2 HP 4039160
ESP-200A 2 HP 4063558
CONSUMER HOT-LINE: 1-800-422-1551
Monday-Friday 7 AM to 5 PM CST
INSTALLATION MANUAL
Lawn Sprinkler for Inground
Sprinkler Systems
WARRANTY: Product defects covered for 12 months from date of purchase.
Receipt is required for warranty claim.

Questions and Answers

  • R
    Roberta FloresAug 9, 2025
    Why Ace Irrigation System pump does not deliver rated capacity?
    • R
      rlawrenceAug 9, 2025
      Several factors could be at play. It might be due to insufficient submergence of the suction pipe; ensure it's at least 3 feet below the water level. Verify that the pump's voltage matches the power supply voltage. Check the valve, suction piping, foot valve, or well point for any issues. The discharge system head might be too great, or the well depth could exceed the pump's capacity. The pump flow might be greater than the well flow capability. Ensure all connections are airtight and that the suction pipe isn't too small; it should be a 1-1/2" pipe.
  • R
    rhowardAug 19, 2025
    What to do if Ace Irrigation System pump will not prime?
    • M
      Michael LopezAug 19, 2025
      If your pump isn't priming, try these steps: Stop the motor, remove the 1-1/2" pipe plug, and fill the case with water. Ensure the pump voltage matches the power supply voltage. Inspect the valve, suction piping, foot valve, or well point. The foot valve might be sitting in sand or mud, stuck shut, or leaking. Check all connections to ensure they are airtight and check for a leaky shaft seal.
  • J
    John HillAug 29, 2025
    Why Ace Irrigation System pump loses prime after starting?
    • S
      Stephanie MartinAug 29, 2025
      The issue might be caused by several reasons. The suction pipe might not be submerged enough; it needs to be at least 3 feet below the water level. The well depth might exceed the pump's capability, or the pump flow might be greater than the well's flow capability. Make sure that all connections are airtight.

Summary

General Safety

Important Instructions Before Installation

Crucial warnings and guidelines to prevent injury and property damage during installation.

Motor Grounding Instructions

Mandatory steps for safe electrical grounding of the pump motor to prevent shock.

Causes of Pump Damage and Warranty Void

List of actions or conditions that can severely damage the pump and void its warranty.

Installation

Troubleshooting

Troubleshooting Checklist

A systematic guide to identify and resolve common pump problems and their causes.

Warranty Information

Limited Warranty Terms and Conditions

Details on warranty coverage, duration, limitations, and exclusions for ACE pumps.

Ace ESP-200A 2 HP Specifications

General IconGeneral
Horsepower2 HP
Motor Power1.5 kW
PhaseSingle
Frequency50 Hz
MaterialCast Iron
Inlet Size2 inch
Outlet Size1.5 inch

Related product manuals