Inverter Electrical Specification:
For Hydis HT17E12-200 (AR577)
Condition Min. Typ. Max. Unit
Input Voltage --- --- 15 --- V
Input Current --- --- 1.5 --- A
ON 3.3 V Backlight ON/OFF Control
OFF 0 V
Brightness Adjust
Min. Luminance / Max.
Luminance
--- 30% --- ---
Output Voltage Vin=15V, Iout=6.5mA 690 700 840 Vrms
Brightness lamp current in 6.5mA 200 250 Cd/m²
Output Current(Each connector) Vbri=0.4V~3.3V 3 6.5 7 mA
Frequency --- 30 --- 70 KHz
Lamp start voltage @0 --- 1340 1570 Vrms
Striking Time --- 1 --- S
Lamp Current Balance --- --- ±0.3 --- mA
Efficiency Vin=15V --- 80 --- %
Operating Life Time --- 40000 50000 --- Hr
*.The open lamp voltage is testes at output connector terminal
SAFETY
Leakage Current: 0.25mA @ 100Vac
Insulation Resistance: more than 3M ohms while withstanding a voltage of 500Vac
Hi-Pot: 3Kvac with using 3mA cut off current