Electrical Requirements
Standard Test Conditions
All tests shall be performed under the following conditions, unless otherwise specified.
Ambient light
225 lux
Viewing distance
40 cm in front of LCD panel
All specifications 30 minutes
Warm up time
Fully functional 5 seconds
Measuring equipment
Chroma 7120 signal generator or equivalent, directly
Connected to the monitor under test.
User brightness control Maximum (unless otherwise specified)
User contrast control Typical (unless otherwise specified)
Control settings
User red/white balance,
Green/white balance and
Blue/white balance control
In the center (unless otherwise specified)
Power input
100Vac or 264Vac
Ambient temperature
20+
5
Analog input mode
1280 x1024 /75 Hz
Measurement systems
The units of measure stated in this document are listed below:
1 gamma = 1 nano tesla
1 tesla = 10,000 gauss
cm = in x 2.54
lb = kg x 2.2
degrees F = [°C x 1.8] + 32
degrees C = [°F - 32]/1.8
u' = 4x/(-2x + 12y + 3)
v' = 9y/(-2x + 12y + 3)
x = (27u'/4)/[(9u'/2) - 12v' + 9]
y = (3v')/[(9u'/2) - 12v' + 9]
Nits = cd/(m2) = Ft-L x 3.426
lux = foot-candle x 10.76