9.4 Rise-Time : 5ns ± 30%
9.5 Impulse Duration: 50 nS ± 30%
9.6 Relation to Power Supply: Asynchronous
9.7 Burst Duration: 15 ms ± 20%
9.8 Burst Period: 300 ms ± 20%
9.9 Climatic Conditions:
- Ambient Temperature: 15°C to 35°C
- Relative Humidity: 45% to 75%
- Atmospheric Pressure: 86 kPa to 106 kPa
9.10 Test Procedure:
The monitor Display set high-resolution mode, AC input use AC 240V.
Note :
9.10.1
IEC 61000-4-4 defines that power supply, I/O line, and control line all shall be performed
the transient test, but the I/O line and control line is applied with only half of peak
voltage (1 KV).
9.10.2
For the comparison of wave-shape generated by different generator, so the test must uses
a scope with at least 400 MHz bandwidth, and coupled to 50 to monitor the rise-time,
impulse, duration, and repetition rate of the impulses within one burst.