Startup Error Messages
7-6
Real time clock error q Realtime clock fails test. This may
require board repair. Contact your
dealer or an authorized service
center.
Shadow Ram Failed at
offset: nnnn
q Shadow RAM failed at offset nnnn
of the 64K block at which the error
was detected. Contact your dealer
or an authorized service center.
System battery is dead
- Replace and run
SETUP
q The CMOS clock battery indicator
shows that the battery is dead.
Contact your dealer or an
authorized service center.
System cache error -
Cache disabled
q RAM cache failed the BIOS test and
BIOS disabled the cache. Contact
your dealer or an authorized service
center.
System CMOS
checksum bad -
run SETUP
q System CMOS has been corrupted
or modified incorrectly, perhaps by
an application program that
changes data stored in CMOS. Run
Setup and reconfigure the system
either by restoring default values
and/or making your own selections.
System RAM Failed at
offset: nnnn
q System RAM failed at offset nnnn of
the 64K block at which the error
was detected. Contact your dealer
or an authorized service center.