SPEC NO.
M T1 8 5GW 0 1 V. 0
PAGE
14/23
Note 4: Test equipment: AS-114B
Note 5: The voltage shown above should be applied to the lamp for more than 1 second after startup.
Otherwise, the lamp may not be turned on normally.
Note 6: Inverter should provide more than min. value, and then lamp could be completely turned on.
Note 7: Lamp frequency may produce interference with horizontal synchronous frequency and this may
cause line flow on the display. Therefore lamp frequency shall be detached from the horizontal
synchronous frequency and its harmonics as far as possible in order to avoid interference.
Note 8: Life time (Hr) is defined as the time when brightness of a lamp unit itself becomes 50% or less
than its original value at the condition of Ta = 25±2°C and IL = 7.5mArms.
Backlight connecter: 3500IHS-02L
Pin no. Symbol Function Remark
1 VIH Lamp high voltage input Cable color: Pink
2 VIL Lamp low voltage input Cable color: White
3 VIH Lamp high voltage input Cable color: Blue
4 VIL Lamp low voltage input Cable color: Black